The TCBHP-1B tests motor stator/rotor cores and wound transformer cores at frequencies from 40 to 500 Hz, measuring flux density B, magnetizing force H and iron loss P. Its purpose is to verify how converting material into a core and subsequent heat treatment change magnetic performance, supporting inspection and monitoring of stator/rotor permeability across different frequency bands — particularly well matched to the wide operating range of new-energy drive motors.
Specifications are from the product manual; models and configurations are subject to the latest technical documentation
| Test Object | Motor stator/rotor cores or wound transformer cores |
|---|---|
| Test Frequency | 40 Hz – 500 Hz |
| Cross-sectional Area | 0 – 8000 mm² |
| Magnetic Path Length | 0 – 1000 mm |
| Flux Density B | 0~2.0 T |
| Magnetic Field Strength H | 0~2000 A/m |
| Iron Loss P | 0 – 320.00 W/kg |
| Magnetizing Method | Variable-frequency AC sinusoidal current magnetization |
| Measurement Accuracy | ±(2.5% + 2 digits) |
| Power / Consumption | AC 220 V, 50 Hz / max. 5 kVA (configurable on request) |
| Dimensions · Weight | W 600 × D 430 × H 700 mm, approx. 85 kg |
※ Specifications, appearance and configuration are subject to the latest technical documentation.
The TCBHP-1A tests the magnetic properties of motor stat
View DetailsThe TCBHP-1D tests the magnetic properties of motor stat
View DetailsCopyright © 2026 Changzhou Sicharm Electronic Technology Co., Ltd. All rights reserved. · Su ICP No. 2026088983