PRODUCTS

Core Magnetic Testing Series

Tell us your sample material, dimensions and target parameters, and our engineers will match the right model

TCBHP-1A Core Magnetic Tester (Standard)
TCBHP-1A

TCBHP-1A Core Magnetic Tester (Standard)

The TCBHP-1A tests the magnetic properties of motor stator/rot

B–H–P parameters16-bit high-speed samplingOD ≤330 mm
View Details
TCBHP-1B Variable-Frequency Core Magnetic Test System
TCBHP-1B

TCBHP-1B Variable-Frequency Core Magnetic Test System

The TCBHP-1B tests motor stator/rotor cores and wound transfor

40–500 Hz inverterP 0–320 W/kg7-inch touch screen
View Details
TCBHP-1D Large Core Magnetic Tester
TCBHP-1D

TCBHP-1D Large Core Magnetic Tester

The TCBHP-1D tests the magnetic properties of motor stator/rot

OD ≤1000 mmStack ≤1000 mmAC 380 V / 10 kW
View Details

Series Selection Comparison

Swipe the table horizontally to see all models

Item TCBHP-1ATCBHP-1BTCBHP-1D
Test Object Motor stator/rotor cores or wound transformer cores Motor stator/rotor cores or wound transformer cores Motor stator/rotor cores or wound transformer cores
Size Range ID 20 mm – OD 330 mm; yoke width 2–200 mm — ID 20 mm – OD 1000 mm; yoke width 10–100 mm
Stack Height / Magnetic Path Stack 10–400 mm; magnetic path 10–1000 mm — Stack 10–1000 mm; magnetic path 10–1500 mm
Flux Density 0~2.0 T 0~2.0 T 0~2.0 T
Magnetic Field Strength 0~1000 A/m 0~2000 A/m 0~1500 A/m
Iron Loss 0~20 W/kg 0 – 320.00 W/kg 0~20 W/kg
Magnetizing Method AC sinusoidal current magnetization Variable-frequency AC sinusoidal current magnetization AC sinusoidal current magnetization
Measurement Accuracy ±(2.5% + 2 digits) ±(2.5% + 2 digits) ±(2.5% + 2 digits)
Power Supply AC 220 V ± 22 V, 50 Hz ± 2 Hz — AC 380 V ± 22 V, 50 Hz ± 2 Hz
Max. Power Consumption 2 KW — 10 KW
Dimensions · Weight W 520 × D 400 × H 600 mm, approx. 45 kg W 600 × D 430 × H 700 mm, approx. 85 kg Customized to the specified parameters
Test Frequency — 40 Hz – 500 Hz —
Cross-sectional Area — 0 – 8000 mm² —
Magnetic Path Length — 0 – 1000 mm —
Power / Consumption — AC 220 V, 50 Hz / max. 5 kVA (configurable on request) —