The TCIL-1A measures the iron loss of single silicon steel sheets. It serves quality control at silicon steel producers, distributors and manufacturers of motors and transformers, mainly for incoming inspection and in-process monitoring. The instrument removes the traditional requirement for a specially prepared coupon — no dedicated test sample is needed — and, by addressing the shortcomings of comparable domestic and international products, resolves the large measurement error and low sensitivity problems they suffer from.
Specifications are from the product manual; models and configurations are subject to the latest technical documentation
| Test Object | Single silicon steel sheet (cold-rolled, hot-rolled, grain-oriented, non-oriented) |
|---|---|
| Size Range | Thickness 0.10–0.99 mm; width ≥25 mm; length ≥25 mm |
| Flux Density B | 1.0~1.7 T |
| Iron Loss P | 0~20 W/kg |
| Test Frequency F | 50 Hz |
| Magnetizing Method | AC sinusoidal current magnetization |
| Measurement Accuracy | ±5% (correlated to the Epstein frame method) |
| Power Supply | 90 V – 240 V |
| Max. Power Consumption | 35 W |
| Dimensions · Weight | W 210 × D 130 × H 280 mm, approx. 3.5 kg |
※ Specifications, appearance and configuration are subject to the latest technical documentation.
The TCIL-2A measures the iron loss of single silicon ste
View DetailsThe TCIL-5A measures the iron loss of single silicon ste
View DetailsThe TCIL-3A measures the iron loss and flux density of s
View DetailsCopyright © 2026 Changzhou Sicharm Electronic Technology Co., Ltd. All rights reserved. · Su ICP No. 2026088983